Job Information

Job ID: Date: 10.09.2007 11:39:37
Reason:
Contractor: Operator A:
Customer: Operator B:
Custom job 1: Custom job 2:

Cable Information

Cable ID: 10002_2    
Location A: Location B:
Cable Mfr.: Cable Type:
Custom cable 1: Custom cable 2:

System Information

  Unit A Unit B
Unit Name: FOT-930 FOT-932
Serial Number: 417390 417389

FasTesT

Fiber ID
Wavelength
 
(nm)
Loss
A->B
(dB)
Ref.
A->B
(dB)
Loss
B->A
(dB)
Ref.
B->A
(dB)
Average
 
(dB)
ORL
A
(dB)
ORL
B
(dB)
Length
 

(km)
FIBER001 1300 1.17 0.77 1.26 0.97 1.22    
0.031
(10.09.2007 11:39:47)
FIBER002 1300 1.07 0.77 1.15 0.97 1.11    
0.035
(10.09.2007 11:40:11)
FIBER003 1300 1.19 0.77 1.28 0.97 1.23    
0.031
(10.09.2007 11:40:26)
FIBER004 1300 1.16 0.77 1.25 0.97 1.20    
0.036
(10.09.2007 11:40:39)
FIBER005 1300 1.55 0.77 1.64 0.97 1.60    
0.034
(10.09.2007 11:40:56)
FIBER006 1300 1.27 0.77 1.37 0.97 1.32    
0.035
(10.09.2007 11:41:10)
FIBER007 1300 1.17 0.77 1.26 0.97 1.21    
0.040
(10.09.2007 11:41:35)
FIBER008 1300 1.20 0.77 1.29 0.97 1.25    
0.034
(10.09.2007 11:41:53)
FIBER009 1300 1.06 0.77 1.15 0.97 1.11    
0.037
(10.09.2007 11:42:11)
FIBER010 1300 1.21 0.77 1.30 0.97 1.25    
0.035
(10.09.2007 11:42:28)
FIBER011 1300 1.09 0.77 1.18 0.97 1.14    
0.035
(10.09.2007 11:42:46)
FIBER012 1300 1.41 0.77 1.50 0.97 1.45    
0.033
(10.09.2007 11:43:02)